3-Rollers / Big Forces
the measuring station - 3 R 100 B 500 / 1000
Measuring ranges:
15N-250N, 25N-500N, 50N-1000N,
75N-1500N, 150-3000N,
With integrated measuring amplifier.
Zero-point adjustment (tare)
and amplification (calibration).
Analog output signal:0-10V or 4mA-20mA
Datasheet 3R 100 B500:
Applied for tensile force measuring of steel wire, copper wire, glass fiber bars and other material of similar toughness, for material diameter up to 6 mm.
extremely large measuring range - Quatt Range
Measuring ranges are set by relocation of the measuring roller:
0-50N, 0-100N, 0-200N, 0-500N,
0- 100N, 0-200N, 0-400N, 0-1000N
With integrated measuring amplifier.
Analog output signal:
0-10V or 4mA-20mA
Zero-point adjustment (tare)
and amplification.
Datasheet Quatt Range:
for thick materials - 3 R 50 A
30N-610N, 60N-1220N,
120N-2440N, 180N-3660N,
240N-4880N, 305N-6100N
With integrated measuring amplifier.
Zero-point adjustment (tare)
and amplification (calibration)
Analog output signal:
0-10V or 4mA-20mA
Datasheet 3R 50A:
for thick materials - 3 R 50 B
7N-144N, 14N-288N, 28N-571N,
43N-857N, 57N-1142N,
With integrated measuring amplifier.
Zero-point adjustment (tare)
and amplification (calibration)
Analog output signal:
0-10V or 4mA-20mA
Datasheet 3R 50B:
2 R 80
Nominal loads are depending on the built-in radial - force measuring head for built-in the series M 1100 - 20 and M 1100 - 6 are available
smallest measuring - range - up to 100 N
biggest measuring - range - up to 2000 N
Vertical-shifting: run-in of the material up to run-out of the material approx. 80 mm
Roller-material: aluminium-alloy AlCuMgPb Option: ceramic coated rollers
Mounting: the mounting plate contains 6 fixing-threads M 8
Technical data: see data-sheets of the radial - force - sensors series
M 1300 - 20 or M 1100 - 6
Accessories available: Tensometric tripod with ground-fixing-holes
Data sheet 2 R 80:
The tensile - force measuring - station 2 R 80 is a space-saving solution for precise measurement of cables, wires, tirecord and other flexible material.
It is equiped with one guiding-roller and one measuring roller. The measuring-roller run on the radial-force-sensor. Both are mounted on a solid plate.
The measuring-station is used, where the angle of contact of the material which is measured, around the measuring-roller, ( where the material run out of the measuring-station ) can be kept constant.
Application: measuring tensile forces on: cables, ropes, wires, tirecord and other flexible material
Characteristics space - saving 2 - roller - system
robust - LC 1322
Measuring ranges:
0-50N, 0-100N, 0-200N, 0-300N,
0- 500N, 0-1000N
With built-in measuring amplifier.
Zero point setting (calibration)
and amplification.
Analog output signal: 0-10V or 4mA-20mA
Datasheet LC1322: