3-Rollers / Tiny Forces
- tiny forces - | - big forces - | - function - |
tiny forces | M 1320 - 1330 | ||||
Ideal to measure the weft of weaving machines. Tensile force measurement on opt. Fibers, wires, yarns, etc. For installation in the production line, also for laboratory operation, optimal for ONLINE measurements. |
Nominal loads: 1 N, 2 N, 3 N, 4 N OR 5 N Measuring range: 1 % to 115% of the nominal load.
Data sheet: |
||||
flat design | LC 1121 | ||||
![]() |
For measuring yarn tension resp. tensile force of fine wires, strands and textile materials Option: Equipped with cylindrical guiding rollers, suitable for measurements at narrow cords and bands. For installing in machines. |
Measuring ranges: 0-2 N, 0-3 N, 0-5 N, 0-10N, 0-20N, 0-30N, 0-50N Also available with integrated measuring amplifier, see LC 1321
Data sheet: |
|||
space saving | LC 1321 | ||||
![]() |
For measuring yarn tension resp. tensile forces on fine wires, strands and textile materials. Option: Equipped with cylindrical guiding rollers, suitable for measuring of narrow cords and bands. For installing in machines. |
Measuring ranges: 0 - 199,9 cN, 0 - 300cN, 0 - 500cN, 0 - 10,00N, 0 - 19,99 N With integrated measusing amplifier. Zero point setting (calibration) and amplification Analog output signal: 0-10V or 4mA-20mA
Data sheet: |
|||
stackable | STAK 1321 | ||||
![]() |
Compact sensor for measuring tensile forces of running materials. The STAK 1321 combines all components in a very flat housing. With minimal effort it can be installed in the production line and is immediately ready for operation.
The position of installation is optional, several sensors can be stacked as a block. |
Measuring ranges: New: our STAK-1321-C up to 300N
Data sheet: |
|||
complete | STAK 310 | ||||
![]() |
A precise and compact measuring instrument for measuring tensile forces of running materials. The STAK 310 combines all necessary components in a stable housing: - Measuring value display - Measuring system with measuring and guiding rollers - Measuring amplifier with analog output - Zero point setting (calibration) - Setting amplification (calibration) With minimal effort it can be installed in the production line and is immediately ready for operation. |
Measuring ranges:
Data sheet: |
|||
for minimum forces |
M 120, M 130 capacitive measuring system |
||||
![]() |
Sensor for measuring very small thread tensions resp. tensile forces within the centiNewton range. With ceramic material guides, for measuring of high-speed materials - or with ball-bearing material guides for avoiding additional friction. A relocatable attachment facilitates catching the material to be measured. Available with integrated measuring amplifier or with connection plug for Tensometric display devices. |
Measuring ranges: 0-10cN, 0-20cN, 0-30cN, 0-50cN, 0-100cN, 0-200cN, 0-300cN With guiding rollers type: M120With fixed ceramic guides type: M130 For connecting the display devices MINI 710 and KT871
Data sheet: |
|||
easy operation |
M 124 capacitive measuring system |
||||
![]() |
Compact sensor for measuring yarn tensions. By using smooth running ball-bearing precision guiding rollers it is possible to measure very small yarn tensions of flexible threads and yarns. |
Measuring ranges:
Data sheet: no data sheet available |
|||
large measuring range |
M 134 capacitive measuring system |
||||
![]() |
The bigger brother of the M 124 sensor. |
Measuring ranges:
Data sheet: no data sheet available |
|||
measuring wires |
M 156 capacitive measuring system |
||||
![]() |
For tensile forces measuring of: wires, strands and textile material. The capacitive measuring system makes possible a minimum deflection of the material to be measured. Three different material guides can be adjusted. Optimal use for measuring by hand as well as by installing in machines. Harmonized with the display devices MINI710, KT871, SA 310 |
Nominal loads:
Data sheet: |
|||
measuring cables |
M 150 capacitive measuring system |
||||
![]() |
The M 150 is a compact sensor for measuring tensile forces of cables, profiles, ribbons, belts etc. The smooth running ball-beared precision guiding rollers can be adjusted to the material to be measured. Threading of the material to be measured is not required. The sensor is only pressed lightly against the material to be measured. Optimal use for measuring by hand as well as by installation in machines. |
Nominal loads:
Data sheet: |
|||
complete - M1356 |
M1356 |
||||
![]() |
A complete measuring device: Sensor, measuring amplifier and display device in one housing. Very slim design with minimum required space. For measuring tensile forces of: thin wires, strands, fibre optics and textile material. Option: Equipped with cylindical guiding rollers, suitable for small ribbons. For installation in machines. |
Analog output signal:
Measuring ranges:
Data sheet: |
|||
M1120 | |||||
![]() |
Series M1120 is a compact sensor for measuring tensile forces on running material. Its special merits are high measuring accuracy and high long-time stability. By means of the two guide-rollers, the material - which is measured - is guided in a defined angle around the measuring-roller. The, at the measuring-roller resulting radial-forces, are measured by the sensor. The radial-force is proportional to the tensile force in the material which is measured. Application tensile force measurement on: fibres, threads, opt. fibres, wires, tapes etc. as well for on-line intallation as for labs. |
Nominal loads: 2N, 5N, 10N, 20N, 30N Measuring range: 1% up to 115% of the nominal load Accessories available: connection-cable amplifier with or without indication custom-made rollers Data sheet: |
|||
M1330 | |||||
![]() |
<to be translated> | Data
Data sheet: no data sheet available |
|||
M1356-LC | |||||
![]() |
Head series M 1356-LC is a compact system to measure tensile forces on: cables, stranded-wire, wires, tapes etc. The smooth, in ball-bearing running rollers, can be adjusted to the material, which should be measured. By means of a light turn, the measuring head can easily be threaded in the running material too. |
Nominal loads: 5 daN, 10 daN, 2 hN, 5 h Analog output signal: