3-Rollers / Tiny Forces
Tensile force measurement on opt. Fibers, wires, yarns, etc.
For installation in the production line, also for laboratory operation, optimal for ONLINE
measurements.
Measuring range: 1 % to 115% of the nominal load.
(Datasheet not available)
Option: Equipped with cylindrical guiding rollers, suitable for measurements at narrow cords and bands. For installing in machines.
0-2 N, 0-3 N, 0-5 N, 0-10N,
0-20N, 0-30N, 0-50N
Also available with integrated measuring amplifier, see LC 1321
Datasheet LC1121:
Option:
Equipped with cylindrical guiding rollers, suitable for measuring of narrow cords and bands. For installing in machines.
0 - 199,9 cN, 0 - 300cN, 0 - 500cN,
0 - 10,00N, 0 - 19,99 N
With integrated measusing amplifier.
Zero point setting (calibration)
and amplification
Analog output signal:
0-10V or 4mA-20mA
Datasheet LC1321:
The position of installation is optional, several sensors can be stacked as a block.
Measuring ranges:
0-2 N, 0-3 N, 0-5 N, 0-10N,
0-20N, 0-30N, 0-50N
New: our STAK-1321-C up to 300N
With integrated measuring amplifier
Zero point setting (calibration)
and integrated amplification
Analog output signal: 0-10 V
Also availabe with integrated digital display (see STAK 310)
Datasheet Stak1321:
- Measuring value display
- Measuring system with
measuring and guiding rollers
- Measuring amplifier with
analog output
- Zero point setting (calibration)
- Setting amplification (calibration)
With minimal effort it can be installed in the production line and is immediately ready for operation.
Measuring ranges:
0 - 199,9 cN, 0 - 300cN,
0 - 500cN, 0 - 10,00N,
0 - 19,99 N
With integrated measuring amplifier.
With integrated measuring
value display.
Measuring amplifier with
analog output.
Zero point setting (calibration)
and amplification (calibration)
Datasheet Stak310:
M 120, M 130 capacitive measuring system
Available with integrated measuring amplifier or with connection plug for Tensometric display devices.
0-10cN, 0-20cN, 0-30cN,
0-50cN, 0-100cN,
0-200cN, 0-300cN With guiding rollers type:
M120With fixed ceramic guides type: M130
For connecting the display devices MINI 710 and KT871
Integrated measuring amplifier
is possible.
Datasheet M120:
M 124 capacitive measuring system
By using smooth running ball-bearing precision guiding rollers it is possible to measure very small yarn tensions of flexible threads and yarns.
Measuring ranges:
0-5dN (50cN), 0-1N, 0-2N,
0-3 N, 0-5N
Easy theading by turing the sensor.
Integrated measuring amplifier possible.
For connection of the display devices MINI 710, SA310 and KT871
Data sheet:
no data sheet available
M 134 capacitive measuring system
Measuring ranges:
0-5N, 0-1daN 0-2daN,
0-3daN, 0-4daN
Integrated measuring amplifier possible.
For connecting the display devices MINI 710, SA310 and KT871
Data sheet:
no data sheet available
M 156 capacitive measuring system
The capacitive measuring system makes possible a minimum deflection of the material to be measured. Three different material guides can be adjusted.
Optimal use for measuring by hand as well as by installing in machines.
Harmonized with the display devices MINI710, KT871, SA 310
Nominal loads:
5daN bis 1kN
Measuring ranges:
0-5daN, 0-10daN, 0-3hN,
0-5hN, 0-1kN
For connecting with display devices MINI 710, SA310 and KT871
Datasheet M156:
M 150 capacitive measuring system
The smooth running ball-beared precision guiding rollers can be adjusted to the material to be measured.
Threading of the material to be measured is not required. The sensor is only pressed lightly against the material to be measured.
Optimal use for measuring by hand as well as by installation in machines.
Nominal loads:
5daN bis 1kN
Measuring ranges:
0-5daN, 0-10daN, 0-3hN, 0-5hN,
0-1kN, 0-2kN, 0-3kN
For connection the display devices
MINI 710 SA 310 and KT871
Datasheet M150:
M1356
Analog output signal:
0-10V or 4mA-20mA
Measuring ranges:
from 0,1-2 N bis 10-200N
Depending from built-in measuring
system and diameter of the assembled guiding rollers.
Datasheet M1356:
The, at the measuring-roller resulting radial-forces, are measured by the sensor. The radial-force is proportional to the tensile force in the material which is measured.
Application tensile force measurement on: fibres, threads, opt. fibres, wires, tapes etc. as well for on-line intallation as for labs.
Measuring range: 1% up to 115% of the nominal load
Accessories available:
connection-cable
amplifier with or without indication
custom-made rollers
Data sheet M1120:
Data sheet:
no data sheet available
Analog output signal:
0-10V or 4mA-20mA
Accessories available:
Connection cable, amplifier with or without display
Data sheet M1356-LC: